Senarai Kelengkapan Elektrik Pengguna yang Dikawal Selia
| Nama Peralatan | Kategori | Perihal | Piawaian Kebangsaan | Piawaian Antarabangsa |
|---|---|---|---|---|
| Capacitors for use in tubular fluorescent lamps and other circuits | CAPACITOR for FLUORESCENT LAMP | is used together with a ballast in a lamp circuit | MS IEC 61048:2019; MS IEC 61049:1999 (confirmed 2015) | IEC 61048:2006 +A1:2015 ; IEC 61049:1991 |
| Magnetic Ballast for tubular fluorescent lamp | BALLAST / CONTROL GEAR / DRIVER FOR LAMP (a) Ballast | for controlling the magnitude of current flow in through the discharge path of a fluorescent lamp; independent or built-in type intended for use with luminaires (portable or fixed); integral type such that it forms a non replaceable part of a fluorescent lamp/ballast combination; or adaptor type such that it allows the insertion of a fluorescent lamp into the ballast by the user; but does not include a ballast which is incorporated in luminaires certified for compliance with the requirements for electrical equipment with increased safety type protection (explosive) for use in hazardous locations. | MS IEC 61347-1:2012; MS IEC 61347-2-8:2003; MS 141:2014 with MS IEC 60921:2013 | IEC 61347-1:2010; IEC 61347-2-8:2000; IEC 60921:2006 with modification |
| Electronic Ballast for fluorescent lamp | BALLAST / CONTROL GEAR / DRIVER FOR LAMP (a) Ballast | is for controlling the magnitude of current flowing through the discharge path of a fluorescent lamp; is of the independent or built-in type intended for use with luminaires; or is of the integral type; or is of the adaptor type | MS IEC 61347-1:2012; MS IEC 61347-2-3:2003; MS IEC 60929:2008 with MS IEC 61000-3-2:2014 | IEC 61347-1:2010; IEC 61347-2-3:2000; IEC 60929:2006 with IEC 61000-3-2:2009 |
| Control Gear | BALLAST / CONTROL GEAR / DRIVER FOR LAMP (b) Control Gear | a lamp control gear for use on dc supply up to 250V and or ac supply up to 1000 V | MS IEC 61347-1:2012 | IEC 61347-1:2010 |
| Electronic Ballast for fluorescent lamp | BALLAST / CONTROL GEAR / DRIVER FOR LAMP (a) Ballast | for controlling the magnitude of current flow in through the discharge path of a fluorescent lamp; independent or built-in type intended for use with luminaires (portable or fixed); integral type such that it forms a non replaceable part of a fluorescent lamp/ballast combination; or adaptor type such that it allows the insertion of a fluorescent lamp into the ballast by the user; but does not include a ballast which is incorporated in luminaires certified for compliance with the requirements for electrical equipment with increased safety type protection (explosive) for use in hazardous locations. | MS IEC 61347-1:2012; MS IEC 61347-2-3:2014; MS IEC 60929:2008 with MS IEC 61000-3-2:2014 | IEC 61347-1:2010; IEC 61347-2-3:2006; IEC 60929:2006 with IEC 61000-3-2:2009 |
| Residual Current Circuit Breaker (RCCB) | CIRCUIT BREAKER including AC CURRENT OPERATED EARTH LEAKAGE CIRCUIT BREAKER and MINIATURE CIRCUIT BREAKER (a) Residual Current Device (RCD) | isolates or initiates a tripping signal to isolate a low voltage supply to protected circuits, socket outlets or equipment in the event of a current flow to earth which exceeds a predetermined level; has a rated residual current less than 300mA for devices intended for connection to fixed wiring or 10mA for other devices; and has a rated load current not exceeding 125 A for devices intended for connection of fixed wiring or 20 A for other devices. But does not include: a device intended to be used with a particular circuit breaker other than a miniature overcurrent circuit breaker; or a device intended to protect an electricity supply authority distribution system | MS IEC 61008-1:2012; MS IEC 61008-2-1:2003 or MS IEC 61008-1:2012; MS IEC 61008-2-2:2003 | IEC 61008-1:2010; IEC 61008-2-1:1990 or IEC 61008-1:2010; IEC 61008-2-2:1990 |
| Residual Current Breaker with Overcurrent Protection (RCBO) | CIRCUIT BREAKER including AC CURRENT OPERATED EARTH LEAKAGE CIRCUIT BREAKER and MINIATURE CIRCUIT BREAKER (a) Residual Current Device (RCD) | isolates or initiates a tripping signal to isolate a low voltage supply to protected circuits, socket outlets or equipment in the event of a current flow to earth which exceeds a predetermined level; has a rated residual current less than 300mA for devices intended for connection to fixed wiring or 10mA for other devices; and has a rated load current not exceeding 125 A for devices intended for connection of fixed wiring or 20 A for other devices. But does not include: a device intended to be used with a particular circuit breaker other than a miniature overcurrent circuit breaker; or a device intended to protect an electricity supply authority distribution system | MS IEC 61009-1:2012; MS IEC 61009-2-1:2003 or MS IEC 61009-1:2012; MS IEC 61009-2-2:2003 | IEC 61009-1:2010; IEC 61009-2-1:1991 or IEC 61009-1:2010; IEC 61009-2-2:1991 |
| Miniature Circuit Breaker (MCB) for ac supply | CIRCUIT BREAKER including AC CURRENT OPERATED EARTH LEAKAGE CIRCUIT BREAKER and MINIATURE CIRCUIT BREAKER (b) Fuse | is an enclosed air-break switch; is opens a low voltage circuit automatically under pre-determined conditions of over-current; has a nominal rating not exceeding 125A and current breaking capacity up to 10kA; is fusion of one or more of its specially designed and proportioned components, opens the circuit in which it is inserted and breaks the current when this exceeds a given value for a sufficient time. The fuse comprises all the parts that form the complete device. | MS IEC 60898-1:2007 | IEC 60898-1:2003 |
| Miniature Circuit Breaker (MCB) for ac & dc supply | CIRCUIT BREAKER including AC CURRENT OPERATED EARTH LEAKAGE CIRCUIT BREAKER and MINIATURE CIRCUIT BREAKER (b) Fuse | is an enclosed air-break switch; is opens a low voltage circuit automatically under pre-determined conditions of over-current; has a nominal rating not exceeding 125A and current breaking capacity up to 10kA; is fusion of one or more of its specially designed and proportioned components, opens the circuit in which it is inserted and breaks the current when this exceeds a given value for a sufficient time. The fuse comprises all the parts that form the complete device. | MS IEC 60898-2:2007 | IEC 60898-2:2003 |
| Fuse Base & Carrier up to 32A | CIRCUIT BREAKER including AC CURRENT OPERATED EARTH LEAKAGE CIRCUIT BREAKER and MINIATURE CIRCUIT BREAKER (b) Fuse | is an enclosed air-break switch; is opens a low voltage circuit automatically under pre-determined conditions of over-current; has a nominal rating not exceeding 125A and current breaking capacity up to 10kA; is fusion of one or more of its specially designed and proportioned components, opens the circuit in which it is inserted and breaks the current when this exceeds a given value for a sufficient time. The fuse comprises all the parts that form the complete device. | MS IEC 60269-1:2011; MS IEC 60296-2:2011 | IEC 60269-1:2006; IEC 60269-2:2006 |